Page 71 - 无损检测2024年第八期
P. 71
试验研究
试验研究
DOI:10.11973/wsjc202408007
活性粉末混凝土盖板钢纤维含量的涡流检测
聂良鹏 ,贠建洲 ,陈顺超 ,孙敬凯 ,黄家琪 ,熊竑瑞 2
2
2
3
2
1
(1. 云南省交通投资建设集团有限公司,昆明 650224;2. 西南林业大学 土木工程学院,昆明 650224;
3. 云南省公路工程监理咨询有限公司,昆明 650500)
摘 要:钢纤维含量对活性粉末混凝土(RPC)盖板的力学性能至关重要,采用康科瑞KON-
RBL(D)型钢筋检测仪,通过电磁感应和涡流效应检测RPC盖板钢纤维含量。首先对测点数和测
试角度进行了研究,然后检测了人工制作的5块盖板,最后检测了27块成品盖板并对其信号值进行
分析,最终确定的测试方案为双面32个测点(单面16个测点),每个测点检测0°和90°两个方向;提
出了RPC盖板钢纤维含量与破坏强度的关系式以及RPC检测信号值与破坏强度的关系式。试验
结果表明,所提方法能够对活性粉末混凝土盖板钢纤维含量进行检测;为钢纤维含量的专门检测提
供了新的设计思路。
关键词:工程材料;活性粉末混凝土;钢纤维;信号值;钢筋检测仪
中图分类号:TG115.28 文献标志码:A 文章编号:1000-6656(2024)08-0037-06
Eddy current testing for steel fibre content in reactive powder concrete cover slabs
NIE Liangpeng , YUN Jianzhou , CHEN Shunchao , SUN Jingkai , HUANG Jiaqi , XIONG Hongrui 2
2
2
3
1
2
(1. Yunnan Transportation Investment and Construction Group Co., Ltd., Kunming 650224, China;
2. School of Civil Engineering, Southwest Forestry University, Kunming 650224, China;
3. Yunnan Highway Engineering Supervision Consulting Co., Ltd., Kunming 650500, China)
Abstract: The steel fibre content is crucial to the mechanical properties of reactive powder concrete (RPC) cover
slabs, the KON-RBL(D) steel rebar tester from Conqueror was used based on electromagnetic induction and eddy current
principle. The experiment firstly studied the number of measuring points and testing angle, then tested 5 pieces of cover
slabs made by experimental values, and the signal values of 27 finished cover slabs were detected and analyzed finally. and
the results showed that the finalized testing scheme was 32 measuring points on both sides (16 measuring points on one
side), and each measuring point was detected in the two directions of 0° and 90°. The relationship equation between the steel
fiber content of the RPC cover slab and the destructive strength was proposed. Experimental results showed that proposed
method can achieve the measurement of steel fibre content of RPC cover slabs to provide new design ideas for steel fibre
content measurement.
Key words: engineering material; reactive powder concrete; steel fibre; signal value; steel bar detector
[1]
活性粉末混凝土(RPC)是一种新型复合材料, 等优点,因此广泛应用于实际工程中 。国内有许
主要由水泥、水、石英砂、矿物掺和料、减水剂以及 多学者对RPC进行了系统的研究,安明喆等 研究
[2]
钢纤维组成。RPC具有高强度、高韧性、高耐久性 发现随着RPC钢纤维含量增加,其劈裂抗拉、轴心
[3]
抗拉强度呈线性增加;邓宗才等 通过试验证明,加
收稿日期:2023-11-06 入钢纤维的RPC材料抗压、抗折强度均得到提高,
基金项目:云南省交通投资建设集团有限公司科技创新项目 且抗折强度增强效果明显高于抗压强度的;寇佳亮
(YCIC-YF-2021-13)
等 研究发现,当钢纤维掺量为3%时,RPC预制板
[4]
作者简介:聂良鹏(1991—),男,硕士,高级工程师,主要研究方
[5]
的抗冲击性能最强;鞠彦忠等 研究了不同钢纤维
向为公路工程试验检测和加固设计
通信作者:贠建洲,yunjianzhou2022@163.com 掺量对RPC抗压强度、劈裂抗拉强度和抗折强度的
37
2024 年 第 46 卷 第 8 期
无损检测