Abstract:
Digital correlation method was used to extract phase information as the phase information of eddy current testing signals could reflect the characteristics of detecting system. The principle of utilizing digital correlation method to detect the phases of the two sine signals with the same frequency was discussed. Digital correlation method combined with statistical analysis was applied to pick up the characteristic information of the crack in electric power locomotive electrode, by which crack was identified successfully.