Performance of CR System and Industrial Film in 9 MeV X-ray Radiography
-
摘要: 采用9 MeV直线加速器X射线源,以工业胶片、VMI高性能5 100MS型CR(计算机射线照相)系统为影像介质,对钢板和固体发动机进行了射线照相,并对影像进行了对比.结果表明,灵敏度测试中CR成像系统性能介于中粒与细粒工业胶片之间,实际缺陷检测能力与中粒工业胶片相当.Abstract: The performance of VMI 5100 MS CR system was studied.Metal plates and a solid propellant engine were radiographed by a 9MeV linear electron accelerator X-ray source.By comparing the radiographs of CR system and industrial films,conclusion was made that the resolution of CR system was between medium and fine grain films,and its performance was equivalent to medium grain film.
-
Keywords:
- CR system /
- Image plate /
- Industrial film /
- X-ray radiography
-
-
[1] 郑世才.CR技术介绍[J].无损探伤,2008,32(5):1-10. [2] 李衍.工业CT技术最新动态[J].影像技术,2010(6):42-48. [3] 陈朝,李仓敏,贾铎默.IP板研究现状与前景展望[J].影像技术,2011(3):3-7. [4] 美国无损检测学会.美国无损检测手册(射线卷)[M].上海:世界图书出版社公司,1992.