Method for Measuring the Density of Spherical Objects by High-Energy Flash X-Ray Radiography
-
摘要: 提出了一种采用高能闪光X光透视成像测量球对称物体内部材料密度的方法——相似样品两次成像对比标定法。介绍了基本原理与过程, 试验考察了测量精度。结果表明, 所用方法对球对称物体密度测量的误差约10%。Abstract: A calibration method for measuring the density of spherical objects by high-energy flash X-ray Radiography is presented. The principle and process is described. A series of measuring experiments demonstrated that the error of density measuring was not greater than 10%.
-
Keywords:
- Flash X-ray radiography /
- Spherical objects /
- Density measuring /
- Calibration method
-
-
[1] 施将君.闪光照相中散射照射量的解析分析[J].强激光与粒子束, 2006, 18(7): 1121-1124. [2] 李必勇.闪光照相系统的散射分布与降散射的数值模拟[J].强激光与粒子束, 2005, 17(5): 788-792. [3] 肖智强.高能闪光照相中陡坡准直体成像性能实验研究[J].核电子学与探测技术, 2007, 27(3): 512-515. [4] 丁伯男.“神龙一号”直线感应电子加速器[J].高能物理与核物理, 2005, 29(6): 604-610. [5] 管永红.高能闪光照相密度测量中的关键技术研究[D].长沙: 国防科技大学, 2007: 50-55.
计量
- 文章访问数: 1
- HTML全文浏览量: 0