Eddy current testing of heat exchange tube and tubesheet expansion section of steam generator in nuclear power plant
-
摘要: 核电站蒸汽发生器传热管与管板胀接位置在制造完成后,必须对其进行检测。利用涡流检测方法对胀管段实施了无损检测,同时对发现的缺陷进行了分析和总结,可为同行在以后的实际检测工作中提供技术参考。Abstract: The quality of the expansion joint of the heat transfer tube of the nuclear power plant steam generator and the tube sheet must be strictly tested while being manufactured. The eddy current testing method is used to implement nondestructive testing of the expanded pipe section. At the same time, the defects found in the testing process are analyzed and summarized, which can provide technical reference for the peers in the actual testing work in the future.
-
Keywords:
- steam generator /
- expand tube /
- eddy current testing
-
-
[1] 石曾伟, 高俊根,刘世辉.核级热交换管子管板胀接及质量控制[J].电站辅机,2013(2):5-8. [2] 谢伟, 范孟豹,曹丙花,等.蒸汽发生器传热管电涡流检测探头响应的理论建模与仿真[J].中国科技论文,2014(8):2-6. [3] 岳娟. 核电蒸汽发生器管子管板液压胀工艺研究[D].广州:华南理工大学,2015. [4] 任吉林, 林俊明,徐可北.涡流检测[M].北京:机械工业出版社,2013. [5] 刘一舟, 曹刚,王晓翔.核电站钛管内壁缺陷判伤曲线[J].无损检测,2010,32(9):719-721.
计量
- 文章访问数: 5
- HTML全文浏览量: 0
- PDF下载量: 5