Improvement of fluorescent background in FPI for turbine blade of aero-engine
-
摘要: 荧光渗透检测某机高压涡轮叶片时,批量性出现荧光背景过度导致无法检测叶片的问题。采用理论和工艺试验相结合的方法,分析了荧光背景过度产生的原因,制定了有效的解决方法,较好地改善了该高压涡轮叶片的荧光背景。Abstract: In the course of the fluorescent penetration inspection for engine turbine blade, appearance of over-fluorescence background will lead to the failure in fluorescence detection for blade. In this paper, the method of combining theory and process test is adopted to analyze the cause of over-fluorescence background, and an effective solution is worked out. Test showed that such solution could greatly improve performance of the fluorescence background for the high-pressure turbine blade.
-
-
[1] 周兆,白海龙,张泽彪,等.荧光渗透法无损检测的原理与应用[J].实验科学与技术,2009,7(1):50-53. [2] 董务江,胡诚,冯佩军. 荧光渗透检测中渗透温度对灵敏度的影响及其对策[J].无损检测, 2017, 39(9): 80-83. [3] 苏清风,戴雪梅,朱晓星.某型高压涡轮工作叶片的荧光渗透检测工艺改进与细化[J].无损探伤,2010,34(3):30-32.
计量
- 文章访问数: 0
- HTML全文浏览量: 0
- PDF下载量: 2