A Pressure Monitoring Gripping Device for Ultrasonic Nonlinear Experiments
-
摘要: 针对通过PZT(锆钛酸铅)晶片-探头穿透法测量非线性系数时,存在测量数据可重复性差的问题,设计了一种辅助RITEC RAM-5000 SNAP非线性高能超声测试系统测量材料非线性的压力监测夹持装置,该装置可实现对材料贴合力度的实时监控,提高逐点测量速度,减小耦合条件对测量结果的干扰。使用结果表明,该装置可大大提高超声波对微小缺陷的灵敏度,增强超声波的穿透率和孔隙检测的精度。Abstract: The non-linear coefficient is measured by the PZT chip-probe penetration method. The measurement data has poor repeatability. In this paper, a pressure monitoring and clamping device for measuring the nonlinearity of materials in RITEC RAM-5000 SNAP nonlinear high-energy ultrasonic testing system is designed. It can realize the real-time monitoring of the bonding force of materials, improve the speed of point-by-point measurement and reduce the interference of the coupling conditions on the measurement results. The results show that the device can greatly improve the sensitivity of ultrasound to micro-defects, and enhance the penetration rate of ultrasound and the accuracy of pore detection.
-
-
[1] 刘玲, 路明坤, 张博明,等. 孔隙率对碳纤维复合材料超声衰减系数和力学性能的影响[J]. 复合材料学报, 2004,21(5):116-121. [2] 李钊.碳纤维复合材料孔隙率超声检测与评价技术研究[D].杭州:浙江大学,2014. [3] 罗明. 碳纤维增强树脂基复合材料孔隙率超声无损检测[D]. 大连:大连理工大学, 2007. [4] 陆铭慧, 徐肖霞. 非线性超声检测方法及应用[J]. 无损检测, 2012, 34(7):61-66. [5] 陆铭慧, 王旭. 非线性超声检测信号提取的电路设计及测试[J]. 失效分析与预防, 2014, 9(1):11-15. [6] 陆铭慧, 李沛芮, 王旭. 复合材料孔隙含量超声多参量评价方法研究[J]. 玻璃钢/复合材料, 2016(3):55-59. [7] 陆铭慧, 刘磨, 张雪松. RTM玻璃纤维复合材料孔隙含量对超声特征参数的影响[J]. 复合材料, 2017, 4(6):33-41. [8] 陆铭慧, 林娜. RTM/纺织复合材料孔隙率非线性超声方法研究[J]. 航空制造技术, 2013, 2(5):89-93. [9] 李沛芮, 陆铭慧. 复合材料孔隙含量超声多参量评价方法及设备研究[D]. 南昌:南昌航空大学, 2016. [10] 祝婧. 基于非线性超声的RTM/纺织复合材料孔隙评价研究[D]. 南昌:南昌航空大学, 2014. [11] 邓燕燕. 碳纤维复合材料孔隙率的超声评价方法研究[D]. 南昌:南昌航空大学,2011.