Alternating Current Field Measurement of the Near-Surface Cracks in Steel Plate
-
摘要: 将金属薄片覆盖在含有人工裂纹的钢板上来模拟近表面缺陷,通过搭建交流电磁场检测的试验平台来提取近表面缺陷的磁场信号。试验得出了近表面裂纹交流电磁场检测的最佳激励频率、最大埋深厚度及影响近表面裂纹检测的因素,以为近表面裂纹的实际检测提供参考。Abstract: In view of the near surface defects detection, steel plates containing artificial cracks were covered with the sheet metal to simulate the near-surface defects, and the experiment platform of ACFM was built to extract magnetic field signal of the near-surface defects. Experimental data were analyzed, and the optimal excitation frequency, the maximum burial depth and related influencing factors of ACFM on near-surface cracks were obtained, which could provide a reference for the practical detection on the near-surface cracks.
-
-
[1] 李健.主动式电磁扫描检测技术及其信号处理方法研究[D].南昌:华东交通大学, 2012. [2] 曹雄恒.矩形线圈激励无损检测技术研究[D].长沙:国防科学技术大学,2002. [3] 魏朋,任尚坤,叶顺科.扰动磁场检测笔试探头的研制及试验分析[J].仪表技术与传感器,2016(7):32-35. [4] 李伟,张传荣,陈国明,等.U型ACFM探头精确建模和实验测试[J].电子测量与仪器学报, 2013,27(7):658-662. [5] 张玉华.金属平板表面缺陷扰动的磁场量分布研究[D].长沙:国防科学技术大学,2003. [6] 李兵,于亮.交流电磁场检测技术在压力容器焊缝检测中的应用[J].检测技术,2016,32(4):47-50. [7] 吴江,周志雄,贾登,等.交流电磁场检测激励频率的有限元模拟优化[J].无损检测, 2016,38(7):1-5.