The Accuracy of Defect Measurement by Eddy Current Testing for Horizontal Steam Generator Tubes
-
摘要: 分析了卧式蒸汽发生器传热管缺陷产生的原因, 通过对含应力腐蚀缺陷传热管的涡流检测结果与缺陷解剖结果对比, 分析了涡流检测误差产生的原因, 总结出缺陷特性对测量结果的影响规律, 为提高涡流检测信号的准确性提供依据。Abstract: The defect mechanism in horizontal steam generator tubes was analyzed, and the results of stress corrosion defects in the tube obtained by eddy current testing and metallographic analysis were compared. Furthermore, the reason of error due to eddy current testing was analyzed. The regularity of effect of different defect characters on testing results is presented.
-
Keywords:
- Steam generator tube /
- Eddy current testing /
- Error analysis /
- Measurement accuracy
-
-
[1] 姚运萍,韩捷.核电站管道缺陷涡流定量检测的可靠性分析[J].核动力工程, 2009,30(4):17-20. [2] 韩捷,廖述圣.蒸汽发生器传热管涡流检验中多缺陷信号判别的可靠性[J].无损检测, 2010,32(12):935-939. [3] 丁训慎.核电站蒸汽发生器传热管的点腐蚀及其防护[J].腐蚀与防护, 2007,21(1):15-18. [4] 徐可北,周俊华.涡流检测[M].北京:机械工业出版社, 2006:21-39. [5] JACKSON J D. Classical Electrodynamics [M] .北京:高等教育出版社, 2004:241-242. [6] DAI X W R. Numerical simulation of pulsed eddy-current nondestructive testing phenomena[J]. IEEE Transactions on Magnetics, 1990,26(6):3089-3096. [7] MARK W C. Theory for coil impedance of a conducting half space: analytic results for eddy current analysis[J]. Journal of Applied Physics, 2001,89(4):2473-2481. [8] 王东升,徐可北,陈星,等.金属薄壁管材涡流检测中异常信号的产生原因[J].无损检测, 2014,36(7):52-55.