• 中文核心期刊
  • 中国科技论文统计源期刊
  • 中国科技核心期刊
  • 中国机械工程学会无损检测分会会刊
Advanced Search
LI Heng-yu, YUAN Gai-huan, FENG Hui. Discussion on Feasibility of U Shape Notch Replacing V Shape Notch in Reference Block for Ultrasonic Testing of Zirconium Tube[J]. Nondestructive Testing, 2007, 29(3): 132-134.
Citation: LI Heng-yu, YUAN Gai-huan, FENG Hui. Discussion on Feasibility of U Shape Notch Replacing V Shape Notch in Reference Block for Ultrasonic Testing of Zirconium Tube[J]. Nondestructive Testing, 2007, 29(3): 132-134.

Discussion on Feasibility of U Shape Notch Replacing V Shape Notch in Reference Block for Ultrasonic Testing of Zirconium Tube

More Information
  • Received Date: November 30, 2005
  • The feasibility of U shape notch replacing V shape notch in the reference block for ultrasonic testing of zirconium tube applied in Candu reactor was analyzed in theory. Using the ultrasonic testing equipment Rota 25 to detect the echo from the U shape notch and V shape notch separately, the obtained echo amplitude was analyzed. The result showed it was reasonable to use U shape notch to replace V shape notch in test blocks for ultrasonic testing of zirconium tube applied in Candu reactor.
  • [1]
    李家伟,陈积懋.无损检测手册[M].北京:机械工业出版社,2002:155.
    [2]
    全国锅炉压力容器无损检测人员资格考核委员会.超声波探伤[M].北京:中国锅炉压力容器安全杂志社,1995.
    [3]
    《国防科技工业无损检测人员资格鉴定与认证培训教材》编审委员会.超声检测[M].北京:机械工业出版社,2005.

Catalog

    Article views (2) PDF downloads (6) Cited by()

    /