Advanced Search
    SI Chun-Jie. Analysis of inaccurate for steel plate on Ultrasonic Gauge-measured Thickness[J]. Nondestructive Testing, 2013, 35(12): 64-66.
    Citation: SI Chun-Jie. Analysis of inaccurate for steel plate on Ultrasonic Gauge-measured Thickness[J]. Nondestructive Testing, 2013, 35(12): 64-66.

    Analysis of inaccurate for steel plate on Ultrasonic Gauge-measured Thickness

    • Sometimes there is a totally thickness data error during the steel plate thickness measurement with an ultrasonic thickness gauge. The reasons caused the error were analyzed and found that ultrasonic thickness gauge had a high testing sensitivity to detect the material defects, such as tiny defect, lamination, material segregation, and material uneven, which all could affect the accuracy and resolution of thickness measurement easily. A suggestion was proposed to take on an ultrasonic testing on the abnormal location to preclude getting an error thickness data for the thickness measurement of the steel plate.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return