Advanced Search
    QI Xiang-Qian. Application of Ultrasonic TOFD Technique on Small Diameter Thick-Wall Pipe[J]. Nondestructive Testing, 2011, 33(7): 29-31.
    Citation: QI Xiang-Qian. Application of Ultrasonic TOFD Technique on Small Diameter Thick-Wall Pipe[J]. Nondestructive Testing, 2011, 33(7): 29-31.

    Application of Ultrasonic TOFD Technique on Small Diameter Thick-Wall Pipe

    • Abstract: Ultrasonic TOFD technique was used to detect the pipe for specification of  80 mm×19 mm. Regulation means of instrument parameters were explained for the wedge block after grinding and sensitivity comparison test was operated on the same thickness steel plate. The experimental result showed that the defect could be detected effectively after the wedge block being worn to the curvature as the pipe to be tested. Compared to the same thickness steel plate, no obvious change was observed for the test sensitivity.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return