The Defect Location in Ultrasonic Testing of Weld on Pipe
-
Graphical Abstract
-
Abstract
Based on the defect location formula of ultrasonic primary wave testing of weld on pipe, the location error caused by K value of angle probe or size of work piece were analyzed, and several correction methods were put forward. The principle of defect location by digital instrument and attention in actual testing were discussed as well.
-
-