Advanced Search
    WEI Peng, ZHOU Changzhi. EMI Analysis and Protective Measures for Industrial UT Detection System[J]. Nondestructive Testing, 2014, 36(8): 76-78.
    Citation: WEI Peng, ZHOU Changzhi. EMI Analysis and Protective Measures for Industrial UT Detection System[J]. Nondestructive Testing, 2014, 36(8): 76-78.

    EMI Analysis and Protective Measures for Industrial UT Detection System

    • Normally there is a lot of electromagnetic interference on our industrial site where ultrasonic test machine is mounted. So it is an extremely important task for researchers whether in design or commissioning phase to suppress or eliminate it from useful ultrasonic echo signals. Here based on the analysis and classification to common electromagnetic interference, this article provides us some valid protective measures especially against largescale ultrasonic test machine with authors many years of related work experience. Meanwhile the effectiveness of these measures has been fully validated in the laboratory tests and customer site tests, which also brings important guiding significance for UT detection system design and practice in antiinterference performance.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return