    YU Run-Qiao, XU Chang-Ying, LUO Shui-Yun, WANG Long-Wen. The Applications of Ultrasonic Testing for PE Pipe[J]. Nondestructive Testing, 2008, 30(2): 112-114.
    Citation: YU Run-Qiao, XU Chang-Ying, LUO Shui-Yun, WANG Long-Wen. The Applications of Ultrasonic Testing for PE Pipe[J]. Nondestructive Testing, 2008, 30(2): 112-114.

    The Applications of Ultrasonic Testing for PE Pipe

    • By measuring the longitudinal and shear wave velocity of PE pipe and its ultrasonic attenuation of hot-melt weld, the acoustic properties of PE pipe was determined. Wavelet denoising technique was used to remove noise, and it improved the monitoring of the echo signal-to-noise ratio. Experiments showed that ultrasonic testing method was suitable for the weld quality testing of PE pipe.