Advanced Search
    WANG Cong, DING Jie, TANG Guoxiang. Verification of national standards for determining for the size of industrial Ir192 gamma radiographic source[J]. Nondestructive Testing, 2025, 47(11): 82-87. DOI: 10.11973/wsjc250139
    Citation: WANG Cong, DING Jie, TANG Guoxiang. Verification of national standards for determining for the size of industrial Ir192 gamma radiographic source[J]. Nondestructive Testing, 2025, 47(11): 82-87. DOI: 10.11973/wsjc250139

    Verification of national standards for determining for the size of industrial Ir192 gamma radiographic source

    • This paper introduced the background of the national standard GB/T 39427—2020 Non-destructive Testing-Testing method for determining the size of Ir192 industrial radiographic source, explained the contents of the standard and expounded the verification test. The standard projected the image of Ir192 radiographic source onto the film, and determined the size of Ir192 radiographic source by measuring the side length of 2D image presented on the radiographs. The test results showed that the film radiography technology specified in this standard could accurately obtain the size of Ir192 radiographic source.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return