Advanced Search
    AN Shiwei, LIU Xunfeng, HU Ke, LIU Kangzheng, CHENG Shuyun, HU Wenjie. Five-axis ultrasonic imaging detection system for copper-steel bonding layer defects in aerospace rotors[J]. Nondestructive Testing, 2023, 45(2): 66-71. DOI: 10.11973/wsjc202302014
    Citation: AN Shiwei, LIU Xunfeng, HU Ke, LIU Kangzheng, CHENG Shuyun, HU Wenjie. Five-axis ultrasonic imaging detection system for copper-steel bonding layer defects in aerospace rotors[J]. Nondestructive Testing, 2023, 45(2): 66-71. DOI: 10.11973/wsjc202302014

    Five-axis ultrasonic imaging detection system for copper-steel bonding layer defects in aerospace rotors

    • Aiming at the problems of low positioning accuracy and poor anti-interference ability of the existing four-axis translational scanning imaging system for detecting aeronautical rotors, a five-axis ultrasonic imaging detection system was developed. The system optimizes the design of the detection workbench, the probe clamping device and the anti-interference device, improves the filtering method, and adds the probe alignment algorithm into the software. The system is used for anti-interference testing, and the positioning accuracy of the system is verified.The experimental results show that the five-axis ultrasonic imaging detection system has high positioning accuracy, good imaging effect, can effectively suppress electromagnetic interference, and realize the continuous and stable detection of the rotor.