Advanced Search
    SHANG Jun-min. The Cause of High Accuracy Ultrasonic Thickness Measurement Error of Thin Walled Carbon Steel Pipe[J]. Nondestructive Testing, 2017, 39(3): 80-82. DOI: 10.11973/wsjc201703020
    Citation: SHANG Jun-min. The Cause of High Accuracy Ultrasonic Thickness Measurement Error of Thin Walled Carbon Steel Pipe[J]. Nondestructive Testing, 2017, 39(3): 80-82. DOI: 10.11973/wsjc201703020

    The Cause of High Accuracy Ultrasonic Thickness Measurement Error of Thin Walled Carbon Steel Pipe

    • This paper aims to analyze errors of the high accuracy ultrasonic thickness measurement of thin walled carbon steel pipe in one nuclear power plant. Through theoretical analysis, test verification and site verification, it is verified that the main reasons of error are due to the pipe inner surface roughness, the probe damping and wave attenuation pulse cycles. The principle for selection of high accuracy thickness measuring probe for thin walled carbon steel pipe with rough inner surface is recommended and the requirement for specimen surface roughness is introduced.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return