Advanced Search
    TAO Yu-chun, LIANG Peng-fei, ZHOU Yu, JIANG Da-chao. Evaluation Method of Condensor Thin-walled Titanium Tube Dent Degree by ET Testing[J]. Nondestructive Testing, 2016, 38(5): 38-40. DOI: 10.11973/wsjc201605010
    Citation: TAO Yu-chun, LIANG Peng-fei, ZHOU Yu, JIANG Da-chao. Evaluation Method of Condensor Thin-walled Titanium Tube Dent Degree by ET Testing[J]. Nondestructive Testing, 2016, 38(5): 38-40. DOI: 10.11973/wsjc201605010

    Evaluation Method of Condensor Thin-walled Titanium Tube Dent Degree by ET Testing

    • Thin-walled titanium tube is widely used as heat-exchange tube in nuclear power plant, and nowadays the inner ET testing is wildly used in titanium tube in-service inspection. In this paper we tested the sample tube with dents by ET tester, and made a comparison between the results, and then we found the linear relationship between signal amplitude and the dent area. Based on that, we provide a method to evaluate the dent degree of tubes quantitatively.